Continuous sampling plans pdf
The procedure for designing RChSP 0, i is specified and indexed through standard quality levels. The experimental results assist the practitioners in the quality control process to choose and implement the RChSP 0, i.
Cite this Article: M. Vijila and J. Different industries adopt different types of designing procedure. Hence to suit their needs various designing procedure are followed.
Catherine Grace acceptance sampling plans play a vital role in inspection of the products so as to accept or reject a lot based on sample results.
In order to maintain quality of the lots, strict measures should be adopted in the quality control section. Dodge [4] has introduced the chain sampling plans for such costly or destructive products. OC curves for chain sampling plans has been developed by Clark C. R [1]. Later, Frishman [6] have introduced an extended version of chain sampling plans.
In order to maintain quality of the products strict inspection scheme is to be developed. The aim of this work is to give constraints on the producer to retain the quality of such products and hence RChSP is being developed.
The AOQ curve reveals that a limit is reached at some incoming quality level and after that the outgoing quality improves. Naturally the customer may expect that his products once received should not go beyond the maximum limit of the AOQ.
Hence AOQL sampling plans are developed. This shows that the producer has to conserve the quality products in order to avoid additional expenses. Illustration 1 Determine Relational Chain Sampling Plans for a customer specification of outgoing quality 0. Solution The customer expectation about the outgoing quality is 0.
Illustration 2 Determine the AOQL of relational chain sampling plans for the known sample size with zero non-conformity in the sample. V [7]. Any help is appreciated. Stan Here is the plan as it exists. Sampling frequency code letter based on the number of units in the production interval Table I. We are at about units. So for units it appears I can select code letters A through F.
There is a note at the bottom of this table which states : AQLs are provided as indices to simplify use of this table, but have no other meaning relative to the plans. I have the sixth edition of Grant and Leavenworth and it deals with Acceptance Inspection of Continuos Production in chapter They also give you instruction on how to construct OC curves.
The correct distribution is hypergeometric — sampling from a finite population. I will order a copy of Grant and Leavenworth. It seems to be a definitive reference, I keep seeing it referred to, time I got a copy. This topic has 6 replies, 3 voices, and was last updated 17 years, 1 month ago by Whitehurst. Any help is appreciated. Stan Here is the plan as it exists. Sampling frequency code letter based on the number of units in the production interval Table I. We are at about units.
So for units it appears I can select code letters A through F. There is a note at the bottom of this table which states : AQLs are provided as indices to simplify use of this table, but have no other meaning relative to the plans. I have the sixth edition of Grant and Leavenworth and it deals with Acceptance Inspection of Continuos Production in chapter They also give you instruction on how to construct OC curves.
The correct distribution is hypergeometric — sampling from a finite population. I will order a copy of Grant and Leavenworth. It seems to be a definitive reference, I keep seeing it referred to, time I got a copy.
This topic has 6 replies, 3 voices, and was last updated 17 years, 1 month ago by Whitehurst.